VU 570 - Vortex Ultrasonic Flow Sensor |
|
VX 570
- Vortex Flow Sensor for Steam, Gases & Liquids |
|
VD 500
- Flow Meter for FAD Measurement |
|
VA 521 - Compact Inline
Flow Meter for Compressed Air and Other Gas Types |
|
 |
|
 |
|
|
|
|
|
For technical
gases and mixed gases - independent from gas composition |
|
The
high-precision all-rounder with integrated pressure and
temperature compensation |
|
For measuring downstream of the
compressor in wet air up to +200 °C |
|
The ideal device for energy
monitoring in compressed air and other gas systems with many
consumers. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VA 525 - Compact In-line Flow Sensor |
|
VA 550 - Flow Meter for Heavy Duty
Industrial Applications
|
|
VA 570 - Flow sensor for compressed
air and gases
|
|
VA 500 - Flow Sensor
for compressed air & gases |
|
|
|
|
|
|
|
|
|
|
|
The
ideal device for energy monitoring in compressed air and
nitrogen systems with many consumers. |
|
Our extra robust flow meter is
available as ATEX-version for application in explosive
areas |
|
The measuring sections are
available in flanged version or with R resp. NPT thread. |
|
RS 485 interface, Modbus RTU, 4...20 mA analogue output
for m³/h, Pulse output for m³. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VA 520 - Flowmeter with integrated
measuring section
|
|
M-Bus - Industrial gas meter
|
|
PI 500 for e.g. portable flow
measurement
|
|
DS 400 - Flow measurement for
compressed air and gases
|
|
|
|
|
|
|
|
 |
|
|
Flow
meter with newly developed evaluation electronics to record
all measured values digitally. |
|
State-of-the-art industrial gas
meter with M-Bus for compressed air, natural gas, biogas and
many other applications. |
|
The PI 500 is an all-purpose
hand-held measuring instrument for many applications in the
industry. |
|
Consisting of: Chart recorder DS 400 and flow sensor VA
500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flow sensor VA 400 for compressed
air and gases
|
|
Flow sensor VA 420 with integrated
measuring section
|
|
Intelligent chart recorder DS 500
for compressed air and gases
|
|
Intelligent mobile chart recorder -
DS 500 mobile
|
|
|
|
|
|
|
|
|
|
Available in a robust housing with and without display.
Depth scale for accurate installation. Usable from 1/2" to
12" (DN 300). |
|
Intelligent solutions for flow
measurement of compressed air and gases. With and without
flange available. |
|
Up to 12 optional sensors can be
connected. 7" color screen with touch panel. |
|
Energy analysis according to DIN EN ISO 50001, flow
measurement, leakage calculation at compressed air systems. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Chart recorder - DS 400
|
|
Affordable mobile chart recorder in
a case - DS 400 mobile
|
|
VA 409 - Flow direction switch for
compressed air systems
|
|
|
|
|
|
|
|
|
|
|
|
|
3.5"
graphic display with touch screen. Option integrated data
logger. Up to 4 sensor inputs. Option Ethernet / RS 485
interface. |
|
For energy analysis, flow
measurement, leakage calculation at compressed air systems. |
|
Serves for determination of the
flow direction of compressed air and gases especially in
closed circular pipelines and detects smallest changes <0.1
m/s. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Proven flow meters for any
application
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CS
Instruments has been an expert in the field of consumption
measurement and flow measurement for many years and serves
customers worldwide with the most advanced and field proven
flow meters. For this reason, we offer a wide range of tools
for almost any application needs. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
An example:
The consumption sensors of our VA550 and VA570 have been
developed especially for rough industrial
applications. Thanks to their robust,
impact-resistant aluminum die-cast housing, these flow
meters can easily be installed outdoors (IP65). On request,
we also offer an ATEX approval for our flow
meters. Those flow measurement devices can be used up to a
maximum pressure of 100 bar and a
maximum temperature of 180 °C. Our
direct immersion variants are the ideal flow meters for
existing compressed air and gas lines and can be easily
installed and removed under pressure via a ½" ball valve.
Those flow sensors are available with different shaft
lengths and can also be used in very large pipelines > DN
1000 or rectangular ducts. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Why to choose a flow meter made by
CS Instruments
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Within the package of our flow measurement devices there is
always a factory calibration certificate. Optionally, ISO
certificates are also available, which can be traced back to
the national standard. While ISO 1217 (1000
mbar, 20 ° C) is generally used to measure compressed air
flows, DIN1343 (1013 mbar, 0 ° C) is used
to measure most industrial gases. In addition to the
consumption measurement, our flow meters can also be used
for leakage measurement and leak detection. Therefore, our
flow measurement devices are the perfect all-in-one tools to
provide users with all necessary information on possible
energy savings. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
In contrast
to many other working principles, the pressure loss
resulting from our consumption measurement method is
negligible. Each consumption meter can be equipped with
various interfaces and thus ensures the connection to your
control technology, data loggers or evaluation devices.
These include e.g. 4 ... 20mA, pulse, Modbus RTU, M-BUS or
even Ethernet. Our thermal mass flow meters can also cover a
wide range of applications and media. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flow meters from CS Instruments are
suitable for gases like:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
✓ air / compressed air |
✓ carbon dioxide (CO2) |
✓ laughing gas (N2O) |
✓ nitrogen (N2) |
✓ oxygen (O2) |
✓ propane (C3H8) |
✓ argon (Ar) |
✓ hydrogen (H2) |
✓ natural gas |
✓ helium (He) |
✓ methane (CH4) |
✓ vacuum |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Which flow measurement device is
for you?
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All flow meters from CS Instruments work according to the
calorimetric measuring principle. This means, while
measuring the thermal mass flow or standard volume flow, no
additional temperature and pressure compensation is
necessary. The standard volume is a common volumetric unit
used to compare gas quantities at different pressures and
temperatures. In order to meet various standards, the
reference conditions can be set directly on the display of
each flow meter. Thus, our reliable flow meters provide
consumption and flow measurement within the individual
standard our customers wish to use them. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Our philosophy is to help our
customers finding the products that exactly meet with their
needs. Therefore, we are looking forward to giving you a
free consultation which flow meter or flow measurement
equipment would be the correct choice for your individual
application requirements. |
|
|
|
|
|
|
|
|
|
|
|
|
|